Plateau simulation test

Plateau simulation test

Technical parameters of plateau simulation 

system (three sets)

Engine intake flow: 

1500/3500/12000 kg/h

Corresponding engine power: 

300/560/1800 kW

Plateau system pressure control range

 (absolute pressure) : 46Kpa-100kpa

System pressure control accuracy: 

steady state ±0.5kPa, transient ±1.5kPa

Discharge capacity (0-4500m) : 

gas emission, smoke FSN

Project experience:

Tianjin University Plateau simulation 

equipment (7000kg/h air intake)

Light bench Plateau simulator 

(1500kg/h air intake)

Plateau simulator (3500kg/h intake)

Super large platform Plateau + 

High temperature +

high cold (12000kg/h air intake)